false
OasisLMS
Login
Catalog
SHM Converge Scientific Abstract ePoster Gallery
Pacemaker Extrusion: A Rare and Challenging Compli ...
Pacemaker Extrusion: A Rare and Challenging Complication in Cardiac Device Therapy
Back to course
Pdf Summary
This poster is a quick-start guide for creating a virtual wide-screen (16:9) PowerPoint presentation poster. It explains how to verify the correct template size before editing, lists compatible print sizes, and gives basic instructions for zooming, using rulers and guides, editing section headers, and adding content. It also notes that guides can be hidden, columns can be reconfigured, and posters can be previewed before printing. Additional help resources and links are provided.<br /><br />The scientific poster describes a clinical case of a 65-year-old man with atrial fibrillation, cardiomyopathy, complete heart block, prior valve surgery, and a history of Staphylococcus epidermidis endocarditis. He presented with an exposed cardiac resynchronization therapy defibrillator (CRT-D) generator after minor trauma but had no fever, stable vital signs, and negative blood cultures. The poster emphasizes that any exposed cardiac implantable electronic device should be considered infected, even without systemic signs.<br /><br />Management involved multidisciplinary electrophysiology and infectious disease consultation, empiric antibiotics, percutaneous laser extraction of the CRT-D system, and implantation of a leadless pacemaker. Cultures grew Staphylococcus epidermidis and Corynebacterium. He then received six weeks of IV vancomycin and metronidazole followed by lifelong doxycycline suppression.<br /><br />The discussion highlights that generator erosion/extrusion is a serious complication, and current guidelines recommend complete device extraction because conservative treatment has high recurrence and mortality risk. The conclusion is that prompt, guideline-directed, multidisciplinary management of exposed devices can lead to favorable outcomes, and long-term suppressive antibiotics may be needed in high-risk patients.
Asset Subtitle
Khola Khan
Meta Tag
Author List
Khola Khan, Megan Brooks
Category
Clinical Vignettes
Concept
Cardiac Implantable Electronic Device
Concept
Device Infection
Concept
Complete System Extraction
Concept
CIED Erosion
Concept
CIED Extrusion
Distinguished
Non-Finalist
Presenter Organization
Ochsner Health
Presenting Author
Khola Khan
Track
Adult
Keywords
PowerPoint poster
16:9 widescreen
scientific poster
template size
print sizes
zoom and guides
clinical case
CRT-D exposure
device infection
leadless pacemaker
Cardiac Implantable Electronic Device
Device Infection
Complete System Extraction
CIED Erosion
CIED Extrusion
×
Please select your language
1
English